Our Store
Digital multimeter AC/DC DVM895
Digital multimeter, suitable for measuring AC/DC current, AC/DC voltage, resistance, capacitance, diodes, continuity, frequency and temperature, including test leads
DVM895
Product description
Multimeters are small meters that do not cost much, but can save costs by detecting sources of error. Whether you are a professional who works with electronics on a daily basis or an enthusiastic DIYer who likes to DIY, this digital multimeter offers reliable and accurate results. The multimeter is equipped with features such as automatic polarity indication and zero setting, allowing you to make accurate measurements effortlessly. With a wide range of measurement ranges, you can make voltage measurements up to 600 VAC/DC, current measurements up to 15 A and resistance measurements up to 200M Ohms. A vibration alarm indicates when readings are available. Moreover, it comes with separate measurement leads, so you can get started right away. The meter also supports frequency measurements up to 20 kHz. This allows you to accurately measure the frequency of electrical signals, providing essential information for various applications, such as checking the operation of electronic devices, detecting faults and analysing signal sources.
+
High accuracy with 1999 counts: This multimeter offers high accuracy in measuring various electrical values such as voltage (volts), current (amps) and resistance (ohms).
+
Safe electrical measurements: The instrument complies with safety category CAT III 600 V / CAT IV 300 V for increased safety.
+
Frequency measurements up to 20 kHz: Accurately measure the frequency of electrical signals and obtain important information for various applications.
+
Automatic polarity indication: Thanks to the automatic polarity indication, you don't have to worry about connecting the test leads incorrectly. This saves time and minimises errors when making measurements.
+
Automatic zero setting: The automatic zero setting ensures accurate measurements. This feature ensures that any zero deviations are compensated for, giving you reliable measurement results without having to make manual adjustments.
Multimeters are small meters that do not cost much, but can save costs by detecting sources of error. Whether you are a professional who works with electronics on a daily basis or an enthusiastic DIYer who likes to DIY, this digital multimeter offers reliable and accurate results. The multimeter is equipped with features such as automatic polarity indication and zero setting, allowing you to make accurate measurements effortlessly. With a wide range of measurement ranges, you can make voltage measurements up to 600 VAC/DC, current measurements up to 15 A and resistance measurements up to 200M Ohms. A vibration alarm indicates when readings are available. Moreover, it comes with separate measurement leads, so you can get started right away. The meter also supports frequency measurements up to 20 kHz. This allows you to accurately measure the frequency of electrical signals, providing essential information for various applications, such as checking the operation of electronic devices, detecting faults and analysing signal sources.
Specifications
Product basic info
Instruction manual languages
Dutch, English, French, German, Polish, Portuguese, Spanish
Primary colours
Black
Additional colours
Red
Depth unit
40 mm
Height unit
190 mm
Width unit
100 mm
Weight unit
300 g
Material
ABS
Physical properties
Cable length
0.75 m
Display height
36 mm
Display width
62 mm
Backlight
Maximum digits display
1999
Display type
LCD
Electrical data
AC current
- basic accuracy: ± (1.5% rdg + 3 digits), ± (2.0% rdg + 3 digits) for 200mA range, ± (2.5% rdg + 5 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
- frequency range: 40-500 Hz
AC voltage
- basic accuracy: ± (0.8% rdg + 3 digits) , ± (1.2% rdg + 3 digits) for 600 V range
- input impedance: 1 megohm for 2 V range, 10 megohm for other ranges
- frequency range: 40-500 Hz
- maximum input: 600V DC or AC rms
- test A: <= or <=
- test B: >= or >=
Audible continuity measurement
Audible continuity
- built-in buzzer sounds if resistance is less than 50 Ohm
- test voltage: approx. 3 V
Automatic polarity indication
Capacity
- basic accuracy: ± (2.5% rdg + 10 digits) for 2000 pF range, ± (2.5% rdg + 5 digits) for 20nF to 20 µF range, ± (5.0% rdg + 10 digits) for 200 µF range
- overload protection: 500 mA / 600 V fuse
DC current
- basic accuracy: ± (1.2% rdg + 2 digits), ± (1.5% rdg + 2 digits) for 200mA range, ± (2.0% rdg + 3 digits) for 15 A range
- overload protection: 500 mA / 600 V, 15 A / 600 V fuse
DC voltage
- basic accuracy: ± (0.5% rdg + 2 digits) , ±(0.8% rdg + 2 digits) for 600 V range
- input impedance: 10 MOhm
- maximum input: 600 V
- overload protection: 600 V DC or AC rms
Diode test
Diode test specifications
test voltage: approx. 3 V (reversed DC voltage)
Frequency
- basic accuracy: ± (2.0% rdg + 5 digits)
- overload protection: 600 VDC or AC rms
- sensitivity: sine wave 0.5 V rms
Fuse type
F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA
Out of range indication
Temperature measuring Celsius specifications
- -50 - 150 °C / 150 - 800 °C
- basic accuracy:
- ± (3 °C + 3 digits) for -50 - 150 °C range
- ± (3 % + 3 digits) for 150 - 800 °C range
- overload protection: 500 mA / 600 V fuse
- NiCr-NiSi sensor
- K thermocouple probe: included
Transistor test
AC current measurements
15 A, 2 mA, 20 mA, 200 µA, 200 mA
AC voltage measurements
0-2 V, 20 V, 200 V, 600 V
Capacity measurements
2 µF, 20 nF, 200 µF, 200 nF, 2000 pF
DC current measurements
0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA
DC voltage measurements
0-200 mV, 2 V, 20 V, 200 V, 600 V
Frequency measurements
20 kHz
Resistance measurements
0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm
Resistance specifications
- basic accuracy: ± ( 1.0% rdg +3 digits) for 200 Ohm range, ± (1.0% rdg + 2 digits) for 2 KOhm to 2 Mohm range, ± (1.5% rdg + 3 digits) for 20 MOhm range, ± (5.0% rdg + 5 digits) for 200 MOhm range
- overload protection: 600 VDC or AC rms
Technical data
Safety rating
Cat III / 600 V, Cat IV / 300 V
Voltage tester type
AC / DC
Automatic power-off function
Pollution degree
2
Data-hold function
Environmental data
IP rating
IPx0
Usage location
Indoor only
Maximum operating temperature °C
40 °C
Maximum operating temperature °F
104 °F
Maximum storage temperature °C
60 °C
Maximum storage temperature °F
140 °F
Minimum operating temperature °C
0 °C
Minimum operating temperature °F
32 °F
Minimum storage temperature °C
-20 °C
Minimum storage temperature °F
-4 °F
Maximum storage humidity
90 %
Maximum operating humidity
80 %
Operational properties
Maximum measuring temperature °C
800 °C
Minimum measuring temperature °C
-50 °C
Range setting
Manual
Power supply
Batteries included
Number of batteries
1
Low battery indicator
Battery composition
Alkaline
Battery IEC size
E (6LR61, 6LP3146, 6F22, 6KR61, 6HR61 ,1604A, 1604D, 1604LC, 7.2H5, 11604, 11604M, PP3, 9-volt, 006P, MN1604)
Included
Set contents
test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm
| Product basic info | |
|---|---|
| Instruction manual languages | Dutch, English, French, German, Polish, Portuguese, Spanish |
| Primary colours | Black |
| Additional colours | Red |
| Depth unit | 40 mm |
| Height unit | 190 mm |
| Width unit | 100 mm |
| Weight unit | 300 g |
| Material | ABS |
| Physical properties | |
|---|---|
| Cable length | 0.75 m |
| Display height | 36 mm |
| Display width | 62 mm |
| Backlight | |
| Maximum digits display | 1999 |
| Display type | LCD |
| Electrical data | |
|---|---|
| AC current |
|
| AC voltage |
|
| Audible continuity measurement | |
| Audible continuity |
|
| Automatic polarity indication | |
| Capacity |
|
| DC current |
|
| DC voltage |
|
| Diode test | |
| Diode test specifications | test voltage: approx. 3 V (reversed DC voltage) |
| Frequency |
|
| Fuse type | F 0.50 A / 600 VAC / 500 VDC, 5 x 20 mm, breaking capacity 1 kA, F 15 A / 1000 VAC / 1000 VDC, 6 x 32 mm, breaking capacity 10 kA |
| Out of range indication | |
| Temperature measuring Celsius specifications |
|
| Transistor test | |
| AC current measurements | 15 A, 2 mA, 20 mA, 200 µA, 200 mA |
| AC voltage measurements | 0-2 V, 20 V, 200 V, 600 V |
| Capacity measurements | 2 µF, 20 nF, 200 µF, 200 nF, 2000 pF |
| DC current measurements | 0.2 mA, 15 A, 2 mA, 20 mA, 200 µA, 200 mA |
| DC voltage measurements | 0-200 mV, 2 V, 20 V, 200 V, 600 V |
| Frequency measurements | 20 kHz |
| Resistance measurements | 0-200 Ohm, 2 kOhm, 2 MOhm, 20 kOhm, 20 MOhm, 200 kOhm, 200 MOhm |
| Resistance specifications |
|
| Technical data | |
|---|---|
| Safety rating | Cat III / 600 V, Cat IV / 300 V |
| Voltage tester type | AC / DC |
| Automatic power-off function | |
| Pollution degree | 2 |
| Data-hold function | |
| Environmental data | |
|---|---|
| IP rating | IPx0 |
| Usage location | Indoor only |
| Maximum operating temperature °C | 40 °C |
| Maximum operating temperature °F | 104 °F |
| Maximum storage temperature °C | 60 °C |
| Maximum storage temperature °F | 140 °F |
| Minimum operating temperature °C | 0 °C |
| Minimum operating temperature °F | 32 °F |
| Minimum storage temperature °C | -20 °C |
| Minimum storage temperature °F | -4 °F |
| Maximum storage humidity | 90 % |
| Maximum operating humidity | 80 % |
| Operational properties | |
|---|---|
| Maximum measuring temperature °C | 800 °C |
| Minimum measuring temperature °C | -50 °C |
| Range setting | Manual |
| Power supply | |
|---|---|
| Batteries included | |
| Number of batteries | 1 |
| Low battery indicator | |
| Battery composition | Alkaline |
| Battery IEC size | E (6LR61, 6LP3146, 6F22, 6KR61, 6HR61 ,1604A, 1604D, 1604LC, 7.2H5, 11604, 11604M, PP3, 9-volt, 006P, MN1604) |
| Included | |
|---|---|
| Set contents | test lead probe : CAT III 1000 V / CAT IV 600 V, 15 A, L = 75 cm |