Our Store
DIGITAL CLAMP MULTIMETER CAT III
DIGITAL CLAMP METER - CAT III - 600 V - AC - with data-hold function
Product description
Features
LCD display with automatic negative polarity indication
auto range control
data-hold function
AC and DC voltage measurements up to max. 600 V
AC current measurement up to max. 500 A
max. Ø for conductor: 22 mm
resistance measurements: max. 20 Mohm
diode test, continuity test
safety: indoor use only (overvoltage CAT III 600 V)
Important safety information
Specifications
DC voltage: 0.2 / 2 / 20 / 200 / 600 V
basic accuracy: ± (0.8% of rdg + 3 digits) for 0.2 V range / ± (1.2% of rdg + 3 digits) for 2 V ~ 600 V range
input impedance: 10 Mohm
maximum input: 600 V
AC voltage: 2 / 20 / 200 / 600 V
basic accuracy: ± (1.5% of rdg + 3 digits) for 2 V ~ 200 V range / ± (1.5% of rdg + 5 digits) for 600 V range
input impedance: 10 Mohm
frequency range: 50-60 Hz
maximum input: 600 V
DC current: -
basic accuracy: -
overload protection: -
AC current: 2 / 20 / 200 / 500 A
basic accuracy: ± (4.0% of rdg + 10 digits) for 2 A range / ± (2.5% of rdg + 5 digits) for 20 A ~ 500 A range
overload protection: -
resistance: 200 / 2K / 20K / 200K / 2M / 20M
basic accuracy: ± (1.0% of rdg + 2 digits) for 200 ohm range / ± (1.5% of rdg + 2 digits) for 2 K ~ 2 M range / ± (2.0% of rdg + 3 digits) for 20 M range
overload protection: 15 s max. 250 V (all ranges)
capacitance: -
accuracy: -
inductance: -
accuracy: -
frequency: -
basic accuracy: -
overload protection: -
temperature: -
basic accuracy: -
overrange: yes "OL"
continuity buzzer: yes
transistor test: -
diode test: yes
low-battery indication: yes
maximum display: 1999
LCD display size: 18 x 39 mm
ranging mode: auto/manual
data hold: yes
backlight: -
dimensions: 131.5 x 61 x 24.8 mm
weight: 135 g
power supply: 3 x 1.5 V AAA LR03 battery (incl.)
packaging: box
accessories: manual / test leads / battery
auto power-off: yes